master index AUTONOMOUS SYSTEMS VISUAL AND AURAL ANALOG TRANSMITTERS

TRAFFIC PACKETS OF TOWNSEND TRANSMITTERS MCUS



! e L L A0 A1 A2 A3 A4 A6 ! crc  SOFT aur LOWER limit sets
! e L H A0 A1 A2 A3 A4 A6 ! crc  SOFT aur UPPER limit sets
! f L L A0 A1 A2 A3 A4 A6 ! crc  SOFT vis UPPER limit sets
! e H N ! crc  HARD Execute HV BEAM ONN TRX RESTART C2
! e H O ! crc  HARD Execute HV BEAM OFF C5
! e O N ! crc  HARD Execute OVERLOAD RESET C0
! e U D ! crc  SOFT Execute DISABLE AUTO functions
! e U I ! crc  SOFT Execute INABLE AUTO functions
! X H N ! crc  HARD Execute BOTH (ALL) RESTART
! X H O ! crc  HARD Execute BOTH (ALL) OFF
! e P U ! crc  HARD Execute adj aur EXITATION up C4
! e P D ! crc  HARD Execute adj aur EXITATION down C3
! f P D ! crc  HARD Execute adj vis EXITATION down
! e E N ! crc  Execute ENG ONN (ENG or RED) C1 latch
! e E O ! crc  Execute ENG ONN (ENG or RED) C1 latch
ä crc               ACK acknowledgement of any command

! X H N ! crc  Execute BOTH (ALL) RESTART
001255 000008     ! X H N ! crc
Commands do not have to be specific to either visual or aural transmitters. Consider the addressing preload...

TO DESTINATION GROUP:
   group (001) (transmitters)
  Only the GROUP of transmitters.
TO SPECIFIC ID
  (255) specific ID's. (255=ALL)
  But ALL units of transmitters.
FROM SOURCE GROUP:
  (000) Human source.
FROM SOURCE SPECIFIC ID:
  (008) A machine located in CHICO.
PERSONALITY is X
  (X) to address the same personality X BOTH.
RULERMAR.GIF, 1 kB ON BOARD INDICATORS
BANASTAR.gif, 1 kB C0 OVERLOAD RESET C0
BANASTAR.gif, 1 kB C1
BANASTAR.gif, 1 kB C2 HV BEAM ONN, TRX RESTART C2
BANASTAR.gif, 1 kB C3 aur EXITATION down C3
BANASTAR.gif, 1 kB C4 aur EXITATION up C4
BANASTAR.gif, 1 kB C5 HV BEAM OFF C5
BANASTAR.gif, 1 kB C6 vis EXITATION down C6
BANASTAR.gif, 1 kB C7 vis EXITATION up C7
RULERMAR.GIF, 1 kB


THE ANALOG PACKET
? e A ? K C QUERY ANALOG values
¿ e A
08  RF PWR=DEMOD             (analog)   byte08   VIS 2.7V  AUR 1.75V
09  RF SWR                   (analog)   byte09   
10  BEAM VOLT KV             (analog)   byte10   VIS 0.63V AUR 0.492V
11  BEAM CURRENT 2           (analog)   byte11   VIS 1.72v AUR 1.45V

12  TIME STAMP HOURS                    byte12   
13  TIME STAMP MINUTES                  byte13   
14  TIME STAMP SECONDS                  byte14   
15  TIME STAMP CENTISECS                byte15   

16  FILAMENT VOLT            (analog)   byte16   VIS 2.72V AUR 2.709V

17  ALARM LOWS               (bit mapped 0123-5--)      byte17
  17-ALARMLO.0=hard PORTA.0 RF PWR        has been low   (dig=1)
  17-ALARMLO.1=hard PORTA.1 RF SWR too low to read       (dig=1)
  17-ALARMLO.2=hard PORTA.2 BEAM VOLT KV  has been low   (dig=1)
  17-ALARMLO.3=hard PORTA.3 BEAM CURRENT  has been low   (dig=1)
  17-ALARMLO.4=hard PORTA.4 1440VIR PRESENT  (5V=PRESENT)(dig=1)
  17-ALARMLO.5=hard PORTA.5 FILAMENT VOLT has been low   (dig=1)        
  17-ALARMLO.6=soft                                      (dig=1)
  17-ALARMLO.7=soft                                      (dig=1)            

18  ALARM HIGHS  (bit mapped 0123-5--)      byte18
  18-ALARMHI.0=hard PORTA.0 RF PWR        has been hi    (dig=1)
  18-ALARMHI.1=hard PORTA.1 RF SWR        has been hi    (dig=1)
  18-ALARMHI.2=hard PORTA.2 BEAM VOLT KV  has been hi    (dig=1)
  18-ALARMHI.3=hard PORTA.3 BEAM CURRENT  has been hi    (dig=1)
  18-ALARMHI.4=hard PORTA.4                              (dig=1)
  18-ALARMHI.5=hard PORTA.5 FILAMENT VOLT has been hi    (dig=1)        
  18-ALARMHI.6=soft                                      (dig=1)
  18-ALARMHI.7=soft                                      (dig=1)            

19               
 
20  CRK         
21  CRC         




THE STATUS PACKET
? d S ? CRK CRC REQUEST of or QUERRY Status
? d = ? CRK CRC REQUEST EQUATE Status
¿ d S REAPLY of Status
= d S EQUATE of Status

BYTE 08 STATUS OPERATIONS         
  08-INDI.0=soft         ENABLED AUTOMATICS              (=1)                                 (=1)
  08-INDI.1=soft         WISH to be ONN AIR              (=1)
  08-INDI.2=soft         ONN AIR CRITERIA MET            (=1)
  08-INDI.3=soft         
  08-INDI.4=soft         
  08-INDI.5=soft                 
  08-INDI.6=soft         
  08-INDI.7=soft         EXECUTE RESTART,OL              (=1)            

BYTE 09                  
  09-empty                   

BYTE 10 STATUS DIGITAL IND
  10-INDI.0=                                             (=1)
  10-INDI.1=soft         EXEC     1440vis  MW70MHzaur    (=1)         
  10-INDI.2=hard PORTB.7 AC3PHASE fail=25v    TB9.3      (=1)
  10-INDI.3=hard PORTB.6 FANS     fail=25v    TB9.5      (=1)
  10-INDI.4=hard PORTB.5 FLOW     fail=25v    TB9.7      (=1)
  10-INDI.5=hard PORTB.4 MAGS     fail=25v    TB9.9      (=1)        
  10-INDI.6=soft         
  10-INDI.7=soft                     
 
BYTE 11 INTERNAL HOUSE KEEPING STATUSES STATes        
  11-STAT.0=RESET initial pwr on ,  WDT RESET
  11-STAT.1=AC POWER has been ABSENT
  11-STAT.2=AC POWER is       ABSENT
  11-STAT.3=ERROR COMMUNICATIONS    Unknown packet, UNKNOWN  
  11-STAT.4=ERROR COMMUNICATIONS    CRC or noise
  11-STAT.5=WAIT  communications too frequent.  UNSTABLE       
  11-STAT.6=NO WISH         WISH.0=ONN WISH.1=OFF
  11-STAT.7=NOT VERIFIED ,  NOT ENABLED.1=DISABLED

12  TIME STAMP HOURS                        byte12   
13  TIME STAMP MINUTES                      byte13   
14  TIME STAMP SECONDS                      byte14   
15  TIME STAMP CENTISECS                    byte15   

16  CRK                   
17  CRC                   


? e = ?                 crc
IDGR=001  (TRANSMITTERS TUSCAN    FORMAL GROUP)
IDGR=001  (TRANSMITTERS COHASSET  FORMAL GROUP)

IDME=101  (TUSCAN AURAL  FORMAL INDIVIDUAL)
PERS=101e (TUSCAN AURAL  PERSONALITY PRONOUN)

IDME=100  (TUSCAN VISUAL FORMAL INDIVIDUAL)
PERS=100f (TUSCAN VISUAL PERSONALITY PRONOUN)

RULERBOW.GIF, 0 kB